Journal of Renal Nutrition
Volume 11, Issue 1 , Pages 23-31, January 2001

Near Infra-Red Interactance for Longitudinal Assessment of Nutrition in Dialysis Patients

Presented, in part, in the 9th annual meeting of the National Kidney Foundation, Atlanta, GA, April 2000.

  • Kamyar Kalantar-Zadeh, MD, MPH

      Affiliations

    • Division of Nephrology and Renal Center, University of California, San Francisco General Hospital, San Francisco, CA.
    • Dr Kalantar-Zadeh was supported by a National Institutes of Health training grant (DK07219).
  • ,
  • Gladys Block, PhD

      Affiliations

    • Professor of Public Health, School of Public Health, University of California Berkeley, Berkeley, CA.
  • ,
  • Mary Pat Kelly, MS, RD

      Affiliations

    • Renal Dietitian, University of California Renal Center, San Francisco General Hospital, San Francisco, CA.
  • ,
  • Concetta Schroepfer, MS, RD

      Affiliations

    • Renal Dietitian, University of California Renal Center, San Francisco General Hospital, San Francisco, CA.
  • ,
  • Rudolph A. Rodriguez, MD

      Affiliations

    • Medical Director, University of California Renal Center, San Francisco General Hospital, San Francisco, CA.
  • ,
  • Michael H. Humphreys, MD

      Affiliations

    • Chief, Division of Nephrology, University of California Renal Center, San Francisco General Hospital, San Francisco, CA.
    • Corresponding Author InformationAddress reprint requests to Michael H. Humphreys, MD, University of California Renal Center, San Francisco General Hospital, 1001 Potrero Ave, Building 100, Room 350, San Francisco, CA 94110.

Objective: Serial nutritional assessment of dialysis patients is important because of the high incidence and prevalence of malnutrition in these patients. Near-infrared interactance (NIR) technology may provide a practical and reliable method to evaluate body fat and its changes over time in dialysis patients.

Design: Longitudinal study consisting of 2 cross-sectional measurements, 2 months apart.

Setting: Outpatient dialysis unit affiliated to a tertiary care community medical center.

Patients: Seventy-one dialysis patients (35 men, 36 women), 57 ± 15 years old, who have been on dialysis between 5 months and 11 years (43 ± 30 months). Twelve additional patients with similar features were studied during the second round.

Intervention: None.

Main outcome measures: NIR was used to estimate the body fat percentage. Other simultaneous measurements included subjective global assessment, anthropometric indices including midarm circumference, triceps and biceps skinfold thickness, and body mass index, and some laboratory values including albumin, transferrin, and cholesterol. NIR measurement was performed by placing a Futrex sensor on the nonaccess upper arm for several seconds, after logging the required individual data (sex, weight, height, and body frame), along with uniform physical activity levels for all patients, into a mini-computer.

Results: Seventy-one dialysis patients underwent nutritional and laboratory measurements. A second measurement round was performed 8 to 9 weeks after the first one and included 12 additional patients. Within each cross-sectional round, Pearson correlation coefficients (r) between the NIR score and nutritionally relevant variables were significant for anthropometric values (0.56 to 0.82) as well as low cholesterol and creatinine (0.22 to 0.30). The two serial NIR measurements on the same patients were highly consistent over the 2-month study interval (r = 0.96), whereas anthropometric values showed greater variability. The within-person coefficient of variation for NIR was low, indicating high consistency between 2 measurements. Moreover, the timing of the NIR measurement (predialysis v postdialysis) did not have any impact on consistency of the NIR results. The longitudinal changes of NIR had significant correlations with anthropometric and laboratory changes over time.

Conclusion: The NIR, which can be performed within seconds, may serve as a reliable and practical tool for objective measurements of nutritional status in hemodialysis patients. The NIR not only seems to have a high degree of reproducibility but may also be an optimal tool to detect longitudinal changes in body fat over time. The NIR measurement is independent of the fluid status in dialysis patients. More comparative and longitudinal studies are needed to confirm the validity of NIR measurements in longitudinal evaluation of dialysis patients.

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1051-2276(01)91938-7

Journal of Renal Nutrition
Volume 11, Issue 1 , Pages 23-31, January 2001